Choose language:

Inspection body for packaging, tanks and bulk containers

Designated inspection bodies for tanks and bulk containers

The inspection bodies designated by DSB, and in-house inspection services authorized by the inspection bodies in accordance with paragraph 32f of the Regulations on the Land Transport of Dangerous Goods are given below. The inspection scopes of each body are listed with references to ADR/RID.

Bruun Inspection

Organization number: 929 775 538
Norwegian-registered foreign business

Business address: Vadgårdsvej 25, 6830 Nørre Nebel, Denmark
Phone: +45 88 27 27 27

Website: https://bruun-inspektion.dk

Designated for:

  • Type approval
  • Initial inspection
  • Periodic inspection
  • Intermediate inspection
  • Extraordinary inspection

for

  • ADR chapter 6.8 Fixed tank (tank-vehicle) with tank shell of metallic material
  • ADR chapter 6.10 Vacuum-operated waste tanks  

Tank stamp:

Stempel bestående av en blå sirkel med B123
 BIXX, where XX is the identification number for each inspector.

Cylinder Tech AS

Organization number: 915 671 691
Business address: Klyvevegen 9, 3740 Skien, Norway

Phone: (+47) 35 59 46 36

Website: https://www.cylindertech.no

Designated for:

  • Periodic inspection
  • Intermediate inspection
  • Extraordinary inspection

for

  • ADR chapter 6.8 Fixed tanks, demountable tanks, tank-containers and tank swap bodies with shells made of metallic material, as well as battery-vehicles/wagons and MEGCs (does not apply to TPED structures).
  • ADR chapter 6.10 Vacuum-operated waste tanks 
  • ADR 6.12 MEMUs (except 6.12.5)

Tank stamp:

Sirkelformet stempel

or

Sirkelformet stempel Xx

where XX = serial number identifying the in-house inspection body that carried out the inspection.

In-house inspection bodies

01 Nik Haugrønning

Organization number: 916 876 157
Business address: Bynesveien 987, 7070 Bosberg, Norway

Approved for: Periodic, intermediate and extraordinary inspection of atmospheric tanks for class 3

Tank stamp:

Sirkelformet stempel 01

02 Krabyskogen Storbilsenter AS

Organization number: 982 771 250
Business address: Krabyskogen, 2850 Lena, Norway

Approved for: Periodic, intermediate and extraordinary inspection of atmospheric tanks for class 3

Tank stamp:

Sirkelformet stempel 02

03 Team Verksted AS

Organization number: 946 930 342 (department Fjeldhus 972 024 201)
Business address: Karihaugveien 102, 1086 Oslo, Norway

Approved for: Periodic, intermediate and extraordinary inspection of atmospheric tanks for class 3

Tank stamp:

Sirkelformet stempel 03

04 IMTAS Harstad 2 AS

Organization number: 933 870 855
Business address: Stangnesveien 51, 9409 Harstad, Norway

Approved for: Periodic, intermediate and extraordinary inspection of atmospheric tanks for class 3

Tank stamp:

Sirkelformet stempel 04

05 Knapphus Storbilverksted AS

Organization number: 934 748 204
Business address: Haukeliveien 497, 5576 Øvre Vats

Approved for: Periodic, intermediate and extraordinary inspection of for class 3

Tank stamp:

Sirkelformet stempel 05

DNV AS (until 01.07.2023)

Organization number: 945 748 931
Business address: Veritasveien 1, 1363 Høvik, Norway

Phone: (+47) 67 57 99 00

Website: https://www.dnv.com

Designated for:

  • Type approval
  • Initial inspection
  • Periodic inspection
  • Intermediate inspection
  • Extraordinary inspection

for

  • ADR/RID Chapter 6.7 Portable tanks and multi-element gas containers in accordance with UN regulations (UN-MEGC)
  • ADR/RID chapter 6.8 Fixed tanks, demountable tanks, tank-containers and tank swap bodies with shells made of metallic material, as well as battery-vehicles/wagons and MEGCs (does not apply to TPED structures).
  • ADR/RID chapter 6.9 (ADR/RID 2021) Tanks made of fibre-reinforced plastic (FRP)
  • ADR/RID chapter 6.9 (ADR/RID 2023) Portable tanks made of fibre-reinforced plastic (FRP)
  • ADR/RID chapter 6.10 Vacuum-operated waste tanks
  • ADR 6.12 MEMUs (except 6.12.5)
  • ADR 6.13 Fixed tanks (tank-vehicles) of fibre-reinforced plastic (FRP) and demountable tanks

Tank stamp : DNV's stamps

DNV's approved workshops until 01.07.2023 for carrying out periodic, intermediate and extraordinary inspections on atmospheric tanks used their own GV stamps.

  • GV1 Team Verksted Øst AS  avd. Fjeldhus,
  • GV2 Krabyskogen Storbilsenter AS    
  • GV7 Nik. Haugrønning  AS
  • GV9 Auto-Tank AS
  • GV10 Martinsens Transport AS  
  • GV11 Knapphus Dekk & Bilverksted  AS  
  • GV12 IMTAS Prosjekt AS

DNV Inspection AS (until 01.09.2024)

Organization number: 927 822 911
Address: P.O. Box 300, 1322 Høvik, Norway

Phone: (+47) 67 57 99 00

Website: https://www.dnv.com

Designated for:

  • Type approval
  • Initial inspection
  • Periodic inspection
  • Intermediate inspection
  • Extraordinary inspection

for

  • ADR/RID chapter 6.7 Portable tanks and multi-element gas containers in accordance with UN regulations (UN-MEGC)
  • ADR/RID chapter 6.8 Fixed tanks, demountable tanks, tank-containers and tank swap bodies with shells made of metallic material, as well as battery-vehicles/wagons and MEGCs (does not apply to TPED structures).
  • ADR/RID chapter 6.10 Vacuum-operated waste tanks
  • ADR 6.12 MEMUs (except 6.12.5)
  • ADR 6.13 Fixed tanks (tank-vehicles) of fibre-reinforced plastic (FRP) and demountable tanks

Tank stamp:
Stempel bestående av bokstavene N og V

or

Stempel bestående av bokstavene N og V med en bue over og under
 
Monthly-L/P-In-house inspection body -GVx

X= Serial No. for approved in-house bodies (workshops) according to the list, e.g. GV1, GV2...

In-house inspection bodies

GV1 Team verksted AS (until 27.09.2024)

Organization number: 972 024 201
Business address: Karihaugveien 102, 1086 Oslo, Norway

Approved for: periodic, intermediate and extraordinary inspections of atmospheric tanks for class 3.

Tank stamp:

Stempel bestående av bokstavene N og V med en bue over og underwhich x = 1

GV9 Auto-Tank (until 27.09.2024)

Organization number: 984 366 787
Business address: Industrivegen 52, 2072 Dal, Norway

Approved for: periodic, intermediate and extraordinary inspections of atmospheric tanks for class 3.

Tank stamp:

Stempel bestående av bokstavene N og V med en bue over og underwhich x = 9

GV11 Knapphus Dekk og Service AS

Organization number: 980 235 149
Business address: Haukelivegen 497, 5576 Øvre Vats, Norway

Approved for: periodic, intermediate and extraordinary inspections of atmospheric tanks for class 3.

Tank stamp:

Stempel bestående av bokstavene N og V med en bue over og underthere x = 11

Dekra Industrial AB

Organization number: 995 031 108
Norwegian-registered foreign company

Business address: Kvarnbergsgatan 2, 401 541 Gothenburg, Sweden
Phone: +46 10 455 1000

Website: https://dekra-industrial.se/sv

Designated for:

  • Type approval 
  • Initial inspection
  • Periodic inspection
  • Intermediate inspection
  • Extraordinary inspection

for

  • ADR/RID chapter 6.8 Fixed tanks, demountable tanks, tank-containers and tank swap bodies with shells made of metallic material, as well as battery-vehicles/wagons and MEGCs (does not apply to TPED structures).
  • ADR/RID chapter 6.10 Vacuum-operated waste tanks
  • ADR 6.12 MEMUs (except 6.12.5)

Tank stamp:
En strektegnet D inne i en sirkel

DEKRA Industrial Oy

Organization number: 932 545 659
Norwegian-registered foreign business

Business address: Tuupakankuja 1, FI-01740 Vantaa, Finland
Phone: +3589878020

Website: https://www.dekra.fi/fi/home/ 

Designated for:

  • Type approval
  • Initial inspection
  • Periodic inspection
  • Intermediate inspection
  • Extraordinary inspection

for

  • ADR/RID chapter 6.8 Fixed tanks, demountable tanks, tank-containers and tank swap bodies with shells made of metallic material, as well as battery-vehicles/wagons and MEGCs (does not apply to TPED structures).
  • ADR/RID chapter 6.10 Vacuum-operated waste tanks
  • ADR/RID chapter 6.11 approval of BK1 or BK2 bulk containers that are not in accordance with CSC
  • ADR 6.12 MEMUs (except 6.12.5)
  • ADR 6.13 Fixed tanks (tank-vehicles) of fibre-reinforced plastic (FRP) and demountable tanks

Tank stamp:
Strektegnet D

Kiwa Sweden AB

Organization number: 989 858 971
Norwegian-registered foreign business

Address: Vänerparken 9B, 462 35 Vänersborg, Sweden
Phone: +46 10 479 30 00

Website: https://www.kiwa.com/se/sv

Designated for:

  • Type approval
  • Initial inspection
  • Periodic inspection
  • Intermediate inspection
  • Extraordinary inspection

for

  • ADR/RID chapter 6.8 Fixed tanks, demountable tanks, tank-containers and tank swap bodies with shells made of metallic material, as well as battery-vehicles/wagons and MEGCs (does not apply to TPED structures).
  • ADR/RID chapter 6.10 Vacuum-operated waste tanks
  • ADR 6.12 MEMUs (except 6.12.5)
  • ADR 6.13 Fixed tanks (tank-vehicles) of fibre-reinforced plastic (FRP) and demountable tanks

Tank stamp:

Bokstavene KIWI trykket inn i metall

Certificates:

Blå bokstaver på grå bakgrunn
 
or

Blå bokstaver på grå bakgrunn

Nortic AS (until 25.11.2025*)

Organization number: 999 267 653
Business address: Ringgata 4, 1723 Sarpsborg, Norway

Phone: +47 48 65 00 00

Website: https://www.nortic.no/

Designated for:

  • Type approval 
  • Initial inspection
  • Periodic inspection
  • Intermediate inspection
  • Extraordinary inspection

for

  • ADR/RID chapter 6.8 Fixed tanks, demountable tanks, tank-containers and tank swap bodies with shells made of metallic material, as well as battery-vehicles/wagons and MEGCs (does not apply to TPED structures).
  • ADR/RID chapter 6.10 Vacuum-operated waste tanks
  • ADR/RID chapter 6.11 approval of BK1 or BK2 bulk containers that are not in accordance with CSC
  • ADR 6.12 MEMUs (except 6.12.5)
  • ADR 6.13 Fixed tanks (tank-vehicles) of fibre-reinforced plastic (FRP) and demountable tanks

Tank stamp:
Stempel bestående av bokstavene NT

*Nortic AS has been granted an exemption to complete approval of bulk containers from Nordic Steel AS

Testlink Oy

Organization number: 932 882 275
Norwegian-registered foreign business

Address: Kangasalatie 152, FI-33730 Tampere, Finland
Phone: +358 40 531 1372

Website: http://testlink.fi/

Designated for:

  • Type approval
  • Initial inspection
  • Periodic inspection
  • Intermediate inspection
  • Extraordinary inspection

for

  • ADR/RID chapter 6.8 Fixed tanks, demountable tanks, tank-containers and tank swap bodies with shells made of metallic material, as well as battery-vehicles/wagons and MEGCs (does not apply to TPED structures).
  • ADR/RID chapter 6.10 Vacuum-operated waste tanks
  • ADR 6.12 MEMUs (except 6.12.5)
  • ADR 6.13 Fixed tanks (tank-vehicles) of fibre-reinforced plastic (FRP) and demountable tanks
  •  

Tank stamp:
Stempel med bokstadene T og L, samt et 1-tall

Stamp on certificate:
Stempel med blå tekst

Designated inspection bodies for packaging

NET Emballasje- og produkttesting AS is the designated inspection body by DSB to approve and control packaging, including IBC and large packaging.

How to apply to be approved?

In Norway, Chapter 6a of the Regulations of 1 April 2009 No. 384 on the Land Transport of Dangerous Goods, applies to the designation of inspection bodies for equipment that is not covered by the Regulations on Transportable Pressure Equipment.

These provisions entered into force on 1 July 2022 with a transition period of one year, so that previous delegations of DSB's authority to other bodies, ceased on 1 July 2023.

Chapter 6a does not apply to:

  • approval, control and testing of packaging, tanks or bulk containers for Class 7 radioactive material
  • approval, control or testing of equipment regulated by the Regulations on Transportable Equipment (the Directive 2010/35/EU).

In addition, there are certain other equipment in Part 6 ADR/RID that are outside the scope of Chapter 6a. Examples are aerosol containers, CSC containers and tanks regulated in 6.12.3.2.

For equipment regulated in the Directive 2010/35/EU, inspection bodies are designated for conformity assessment and periodic inspections in accordance with Section 24 of the Regulations on Transportable Pressure Equipment. This will mainly apply to pressure receptacles tanks, battery-vehicles/wagons and multi-element gas containers (MEGCs) used to transport gases.

Notified bodies that can carry out inspection and approval activities on equipment that are within TPED are listed in the NANDO database.

Enterprises that wish to be designated as an inspection body in the areas to which Chapter 6a applies must submit an application to DSB.

Inspection bodies must be accredited. Businesses are accredited for conformity assessment in accordance with relevant international standards. Notified bodies for tanks and bulk containers shall be accredited in accordance with EN ISO/IEC 17020 type A (except section 8.1.3). Inspection bodies for packaging shall either be accredited in accordance with EN ISO/IEC 17020 type A (except in section 8.1.3) or in accordance with EN ISO/IEC 17025.